4.4.5 Motor protection
The pump requires no external motor protection. The motor
incorporates thermal protection against slow overloading and
blocking (IEC 34-11, TP 211).
4.4.6 Protection against voltage transients
The pump is protected against voltage transients in accordance
with EN 61800-3 and is capable of withstanding a VDE 0160 pulse.
The pump has a replaceable varistor which is part of the transient
protection.
Over time this varistor will be worn and need to be replaced. When
the time for replacement has come, R100 and PC Tool E-products
will indicate this as a warning. See the section on servicing the
product.
Related information
8.1 Cleaning of the motor
4.4.7 Supply voltage
3 x 460-480 V - 10 %/+ 10 %, 50/60 Hz, PE.
The supply voltage and frequency are marked on the pump
nameplate. Make sure that the motor is suitable for the power
supply of the installation site.
The wires in the terminal box must be as short as possible.
Excepted from this is the protective ground lead which must be so
long that it is the last one to be disconnected in case the cable is
inadvertently pulled out of the cable entry.
L1-L3
TM038605
Torques, terminals L1-L3:
Min. torque: 1.6 ft-lbs
Max. torque: 1.8 ft-lbs
TM043048
Power connection
Cable glands
Cable glands comply with EN 50626.
1 x M40 cable gland
1 x M20 cable gland
2 x M16 cable gland
2 x M16 knock-out cable entries.
If the supply cable is damaged, it must be replaced by
qualified personnel.
Grid types
Three-phase E-pumps can be connected to all grid types.
Could result in personal injury
Do not connect three-phase E-pumps to a power supply with a
voltage between phase and ground of more than 440 V.
4.4.8
Start/stop of pump
The number of starts and stops via the power supply must
not exceed 4 times per hour.
When the pump is switched on via the power supply, it will start
after approx. 5 seconds.
If a higher number of starts and stops is desired, use the input for
external start/stop when starting/stopping the pump.
When the pump is switched on via an external On/Off switch, it will
start immediately.
4.4.9 Connections
If no external on-off switch is connected, connect
terminals 2 and 3 using a short wire.
As a precaution, the wires to be connected to the following
connection groups must be separated from each other by reinforced
insulation in their entire lengths:
Group 1: Inputs
start/stop terminals 2 and 3
digital input terminals 1 and 9
setpoint input terminals 4, 5 and 6
sensor input terminals 7 and 8
GENIbus terminals B, Y and A
All inputs (group 1) are internally separated from the power-
conducting parts by reinforced insulation and galvanically separated
from other circuits.
All control terminals are supplied with protective extra-low voltage
(PELV), thus ensuring protection against electric shock.
Group 2: Output (relay signal, terminals NC, C, NO)
The output (group 2) is galvanically separated from other circuits.
Therefore, the supply voltage or protective extra-low voltage can be
connected to the output as desired.
Group 3: Power supply (terminals L1, L2, L3)
G1
G2
G3
TM052986
Connection terminals
8
English (US)

Other manuals for Grundfos CRE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos CRE and is the answer not in the manual?

Grundfos CRE Specifications

General IconGeneral
Protection ClassIP55
MaterialStainless Steel
ApplicationsWater supply, pressure boosting, irrigation
Impeller MaterialStainless Steel
Pump Housing MaterialStainless Steel
Connection SizeDN32 to DN200 (depending on model)
Power Supply3-phase
ControlIntegrated frequency converter