CONTENTS
These installation and operating instructions describe New
MAGNA1 model C.
Sections 1-5 give the information necessary to be able to unpack,
install and start up the product in a safe way.
Sections 6-11 give important information about the product, as
well as information on service, fault finding and disposal of the
product.
Page
1. General information
1.1 Symbols used in this document
The text accompanying the three hazard symbols DANGER,
WARNING and CAUTION is structured in the following way:
1.2 Safety symbols on the pump
1. General information
3
1.1 Symbols used in this document
3
1.2 Safety symbols on the pump
3
2. Receiving the product
4
2.1 Inspecting the product
4
2.2 Scope of delivery
4
2.3 Lifting the pump
4
3. Installing the product
5
3.1 Location
5
3.2 Tools
5
3.3 Mechanical installation
5
3.4 Electrical installation
8
4. Starting up the product
12
4.1 Single-head pump
12
4.2 Twin-head pump
12
4.3 Connecting the pump to Grundfos GO
12
5. Handling and storing the product
13
5.1 Storing the product
13
6. Product introduction
13
6.1 Applications
13
6.2 Pumped liquids
13
6.3 Identification
14
6.4 Insulating shells
14
6.5 Non-return valve
14
7. Control functions
15
7.1 Proportional-pressure curve (PP1, PP2 or PP3)
15
7.2 Constant-pressure curve (CP1, CP2 or CP3)
16
7.3 Constant curve (I, II or III)
16
7.4 Overview of control functions
17
7.5 Selecting control function
18
7.6 Operating the product
19
7.7 Pairing and unpairing twin-head pumps
20
7.8 Communication, control and monitoring
21
8. Fault finding the product
22
8.1 Grundfos Eye operating status
22
8.2 Fault finding
22
8.3 Fault finding table
24
9. Accessories
25
9.1 Insulating kits for air-conditioning and cooling systems
25
9.2 Blanking flanges
25
9.3 Counterflanges
25
10. Technical data
26
11. Disposing of the product
26
Prior to installation, read this document and the quick
guide. Installation and operation must comply with
local regulations and accepted codes of good
practice.
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children
without supervision.
DANGER
Indicates a hazardous situation which, if not avoided,
will result in death or serious personal injury.
WARNING
Indicates a hazardous situation which, if not avoided,
could result in death or serious personal injury.
CAUTION
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate personal injury.
SIGNAL WORD
Description of hazard
Consequence of ignoring the warning.
- Action to avoid the hazard.
A blue or grey circle with a white graphical symbol
indicates that an action must be taken.
A red or grey circle with a diagonal bar, possibly with
a black graphical symbol, indicates that an action
must not be taken or must be stopped.
Notes or instructions that make the work easier and
ensure safe operation.
Check the position of the clamp before you tighten
the clamp. Incorrect position of the clamp will cause
leakage from the pump and damage the hydraulic
parts in the pump head.
Fit and tighten the screw holding the clamp to 8 Nm ±
1 Nm.
Do not apply more torque than specified even though
water is dripping from the clamp. The condensed
water is most likely coming from the drain hole under
the clamp.
8Nm!

Other manuals for Grundfos MAGNA1 C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos MAGNA1 C and is the answer not in the manual?

Grundfos MAGNA1 C Specifications

General IconGeneral
Liquid temperature range-10°C to +110°C
Maximum operating pressure10 bar
Enclosure classIP42
Insulation classF
TypeCirculator pump
Pump housingCast iron
SeriesMAGNA1
ModelMAGNA1 C
Protection ClassIP42
ApprovalsCE, EAC
ConnectionFlange
Power Supply1 x 230 V, 50/60 Hz
WeightVaries by model