WARNING
Electric shock
Death or serious personal injury
- Connect the pump to an external
main switch with a minimum contact
gap of 3 mm in all poles.
- Use earthing or neutralisation for
protection against indirect contact.
- For plug-connected versions: In
case of an insulation fault, the fault
current may be a pulsating DC.
Observe national legislation about
requirements for and selection of
Residual Current Device (RCD)
when installing the pump.
For terminal-connected versions:
In case of an insulation fault, the
fault current may be a DC or
pulsating DC. Observe national
legislation about requirements for
and selection of Residual Current
Device (RCD) when installing the
pump.

Other manuals for Grundfos MAGNA1 C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos MAGNA1 C and is the answer not in the manual?

Grundfos MAGNA1 C Specifications

General IconGeneral
Liquid temperature range-10°C to +110°C
Maximum operating pressure10 bar
Enclosure classIP42
Insulation classF
TypeCirculator pump
Pump housingCast iron
SeriesMAGNA1
ModelMAGNA1 C
Protection ClassIP42
ApprovalsCE, EAC
ConnectionFlange
Power Supply1 x 230 V, 50/60 Hz
WeightVaries by model