6.2.7 Favorites
Favorites are typically used to collect a set of
parameters or monitoring signals from any of the
keypad menus. You can add items or parameters to
the Favorites folder.
To remove an item or a parameter from the Favorites
folder, do the following:
Motor Nom Freq
50.00 Hz
Favorites
STOP READY I/O
Help
Motor Nom Freq
STOP READY I/O
Monitor
Rem from favorites
TM078682
Related information
6.1.5.11 Adding item to favorites
6.2.8 User levels
User level parameters are intended to restrict the
visibility of parameters and to prevent unauthorized
and inadvertent parameterization on the keypad.
Code Parameter Min Max Unit Default ID Description
P8.1 User level 1 3 1 1194
1 = Normal; All menus visible in the Main menu
2 = Monitoring; Only Monitor, Favorites and User
Levels menus are visible in the main menu
3 = Favorites; Only Favorites and User Levels menus
are visible in the Main menu
P8.2 Access code 0 99999 0 2362
If set to other value than 0 before switching to
monitoring when e.g. user level Normal is active, the
access code will be asked when trying to switch back
to Normal. Can therefore be used to prevent
unauthorized
parameterization on the keypad.
STOP READY KeypadALARM
ID:2362 P8.2
User levels
User level
Normal
Access code
00000
STOP READY I/OALARM
00000
Min:0
Max:9
ID:2362 P8.2
Access code
TM078683
Related information
6.2.2 Monitor
60