7. Fault finding the product
7.1 Grundfos Eye operating indications
7.2 Fault resetting
You can reset a fault indication in one of the following ways:
When you have eliminated the fault cause, reset the pump
manually by pressing the button. The pump then reverts to
normal duty.
If the fault disappears by itself, the pump attempts to reset
automatically and the fault indication disappears if automatic
reset is successful and provided that you have enabled "Auto
reset" in the service menu.
Grundfos Eye Indication Description
No lights are on.
The power is off.
The pump is not running.
Two opposite green indicator lights running in the
direction of rotation of the pump.
The power is on.
The pump is running.
Two opposite green indicator lights at a 45 °
angle is the icon used throughout this document
for pump running.
The power is on.
The pump is running.
Two opposite green indicator lights permanently
on.
The power is on.
The pump is not running.
Two opposite red indicator lights flashing
simultaneously.
Alarm.
The pump has stopped.
Two opposite red indicator lights is the icon used
throughout this document for pump stopped.
Alarm.
The pump has stopped.

Other manuals for Grundfos SCALA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos SCALA and is the answer not in the manual?

Grundfos SCALA Specifications

General IconGeneral
Frequency50/60 Hz
Maximum Suction Lift8 m
InstallationHorizontal
ApprovalsCE
Pumped liquidWater

Related product manuals