What does 'Receive buffers capacity was exceeded' mean on my GSE 350 Touch Panel?
- MMichael SawyerAug 29, 2025
The message 'Receive buffers capacity was exceeded' on your GSE Touch Panel indicates a handshaking problem.
What does 'Receive buffers capacity was exceeded' mean on my GSE 350 Touch Panel?
The message 'Receive buffers capacity was exceeded' on your GSE Touch Panel indicates a handshaking problem.
What does it mean when my GSE 350 Touch Panel displays 'Input signal greatly exceeds the valid range'?
This message indicates that the input signal is far beyond what is expected. To resolve this, check the load cell connection of your GSE Touch Panel.
What to do if my GSE 350 displays 'Under Load'?
If your GSE Touch Panel displays 'Under Load', check the load cell wiring.
What does 'Deflt ~ A-D Bad' mean on GSE Accessories?
The message 'Deflt ~ A-D Bad' on GSE Accessories refers to A/D calibration values. Recalibrate A/D.
What does 'T.X.YYYY' mean on GSE Accessories?
The message 'T.X.YYYY' on GSE Accessories means that catastrophic errors occurred in the software, a trap error may occur and freeze the display with address information. Press any key five seconds after viewing message to reboot the unit.
What does 'Add ~ Load!' mean on my GSE 350 Touch Panel after a count sample?
If your GSE Touch Panel displays 'Add ~ Load!' after performing a count sample, it means that a larger sample size is needed.
What does 'Add ~ Load!' mean during calibration on GSE Accessories?
During calibration, the message 'Add ~ Load!' on GSE Accessories means that the calibration weight is less than 0.1% of capacity. More weight is required.
Why does my GSE Accessories show 'Tare ~ Error'?
The message 'Tare ~ Error' on your GSE Accessories indicates a negative tare attempt was made when disabled (P440 enabled).
What does 'Code 05' mean on my GSE Accessories?
If the GSE Accessories display shows 'Code 05', it means a zero attempt was made beyond that allowed by P118.
What does 'Add ~ Load!' mean on GSE Accessories?
If 'Add ~ Load!' is displayed after performing a count sample on your GSE Accessories, this message indicates that a larger sample size is required.
Instructions for sampling and counting parts, including viewing average piece weight.
Guides on entering target values and tolerances for percentage checkweighing.
Instructions for entering target values for the fill program, including pre-act values.
Steps to enter target and pre-act values for batching ingredients in Model 350 and 355.
Instructions for entering target and pre-act values for the discharge program.
How to enter target values for combined fill and discharge operations.
Guides on entering absolute target values and tolerances for checkweighing.
How to enter target values and tolerances for target deviation checkweighing.
Lists and explains common operational error codes and messages encountered.
| Display Type | TFT LCD |
|---|---|
| Touch Panel | Yes |
| Touch Technology | Resistive |
| Power Supply | 24 VDC |
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | -20°C to 60°C |
| Interface | Ethernet |
| Humidity | 10% to 90% non-condensing |
| Protection Level | IP65 |
| Operating Voltage | 24V DC ±10% |