C
cthompsonAug 25, 2025
What does 'Bad ~ Code!' mean on GSE Accessories?
- PPaul JohnsonAug 25, 2025
The message 'Bad ~ Code!' on GSE Accessories indicates that an incorrect access code was entered.
What does 'Bad ~ Code!' mean on GSE Accessories?
The message 'Bad ~ Code!' on GSE Accessories indicates that an incorrect access code was entered.
What does 'Add ~ Load!' mean on GSE Accessories?
If 'Add ~ Load!' is displayed after performing a count sample on your GSE Accessories, this message indicates that a larger sample size is required.
What does 'Code 05' mean on my GSE Accessories?
If the GSE Accessories display shows 'Code 05', it means a zero attempt was made beyond that allowed by P118.
Why does my GSE Accessories show 'Tare ~ Error'?
The message 'Tare ~ Error' on your GSE Accessories indicates a negative tare attempt was made when disabled (P440 enabled).
What does 'Add ~ Load!' mean during calibration on GSE Accessories?
During calibration, the message 'Add ~ Load!' on GSE Accessories means that the calibration weight is less than 0.1% of capacity. More weight is required.
What does 'Prtcl ~ Error' mean on GSE Accessories?
The message 'Prtcl ~ Error' on GSE Accessories means that the existing protocol is invalid. The following are not allowed: ? P201 = 7 data bits, P202 = no parity, P203 = 1 stop bit ? P201 = 8 data bits, P202 = even parity, P203 = 2 stop bits.
What does 'Code00' mean on my GSE Accessories?
If the GSE Accessories display shows 'Code00', it indicates an EPROM problem detected during power-up (U2).
What to do if my GSE Touch Panel displays 'Over load'?
If your GSE Touch Panel displays 'Over load', perform the same checks as you would for an 'under load' situation. This involves inspecting the load cell wiring.
What to do if my GSE 350 displays 'Under Load'?
If your GSE Touch Panel displays 'Under Load', check the load cell wiring.
What does it mean when my GSE 350 Touch Panel displays 'Input signal greatly exceeds the valid range'?
This message indicates that the input signal is far beyond what is expected. To resolve this, check the load cell connection of your GSE Touch Panel.
Instructions for sampling and counting parts, including viewing average piece weight.
Guides on entering target values and tolerances for percentage checkweighing.
Instructions for entering target values for the fill program, including pre-act values.
Steps to enter target and pre-act values for batching ingredients in Model 350 and 355.
Instructions for entering target and pre-act values for the discharge program.
How to enter target values for combined fill and discharge operations.
Guides on entering absolute target values and tolerances for checkweighing.
How to enter target values and tolerances for target deviation checkweighing.
Lists and explains common operational error codes and messages encountered.
| Display Type | TFT LCD |
|---|---|
| Touch Panel | Yes |
| Touch Technology | Resistive |
| Power Supply | 24 VDC |
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | -20°C to 60°C |
| Interface | Ethernet |
| Humidity | 10% to 90% non-condensing |
| Protection Level | IP65 |
| Operating Voltage | 24V DC ±10% |