The specifications apply when the GPD-3303 series are powered on
for at least 30 minutes under +20°C – +30°C.
Output Ratings CH1/CH2
Independent
0 ~ 30V / 0 ~ 3A
CH1/CH2
Series
0 ~ 60V / 0 ~ 3A
CH1/CH2
Parallel
0 ~ 30V / 0 ~ 6A
CH3 2.5V/3.3V/5.0V, 3A
Line
0.01% + 3mV
Voltage
Regulation
Load
0.01% + 3mV (rating current 3A)
0.02% + 5mV (rating current > 3A)
Ripple & Noise
1mVrms (5Hz ~ 1MHz)
Recovery Time
100μs (50% load change, minimum
load 0.5A)
Temperature
Coefficient
300ppm/°C
Current
Regulation
Line
0.2% + 3mA
Load
0.2% + 3mA
Ripple & Noise
3mArms
CH3 Specification
Regulation
Line 5mV
Load 15mV
Ripple & Noise
2mVrms
Tracking
Operation
Tracking Error 0.5%+10mV of Master (GPD-3303S)
0.5%+50mV of Master (GPD-3303D)
Parallel
Regulation
Line: 0.01% + 3mV
Load: 0.01% + 3mV
(rating current 3A)
Load: 0.02% + 5mV
(rating current > 3A)
Series
Regulation
Line: 0.01% + 5mV
Load: 300mV
Meter Resolution
GPD-3303D Voltage: 100mV
Current: 10mA
GPD-3303 Series User Manual
48
GPD-3303S Voltage: 1mV
Current: 1mA
A Meter GPD-3303D 3.2A full scale, 3 digits 0.5" LED
display
GPD-3303S 3.2A full scale, 4 digits 0.4" LED
display
V Meter GPD-3303D 32V full scale, 3 digits 0.5" LED display
GPD-3303S 32V full scale, 5 digits 0.4" LED display
Program
Accuracy
GPD-3303D ± (0.5% of reading + 2digits)
± (0.5% of reading + 2digits)
GPD-3303S ± (0.03% of reading + 10mV)
± (0.3% of reading + 10mA)
Readback
Accuracy
GPD-3303D ± (0.5% of reading + 2digits)
± (0.5% of reading + 2digits)
GPD-3303S ± (0.03% of reading + 10mV)
± (0.3% of reading + 10mA)
Insulation Chassis and
Terminal
20M or above (DC 500V)
Chassis and
AC cord
30M or above (DC 500V)
Operation
Environment
Indoor use, Altitude: 2000m
Ambient temperature 0 ~ 40°C
Relative humidity 80%
Installation category: II, Pollution degree: 2
Storage
Environment
Ambient temperature –10 ~ 70°C
Relative humidity 70%
Power Source AC 100V/120V/220V/230V±10%, 50/60Hz
Accessories User manual x1
Test lead GTL-104 x 2, GTL-105 x 1
(Europe) Test lead GTL-203 x 1, GTL-204 x 2
Dimensions 210 (W) x 130 (H) x 265 (D) mm
Weight Approx. 7kg
48BOptions
USB cable GTL-246 USB 2.0, A-B type