OPERATION 
31 
 
6.  For the master (CH1) output level and CV/CC 
status, refer to the CH1 meter and indicator. 
 
 
 
 Master (CH1) 
voltage level 
CH1 meter reading shows the 
output voltage. In the above case, 
20.0V. 
 Master (CH1) 
current level 
CH1 meter reading shows the 
output current. In the above case, 
2.000A. 
 
7.  Press the CH2 key (LED turns 
on) and use the Current knob 
to set the slave output current.
 
 
 
8.  For the slave (CH2) output level and CV/CC 
status, refer to the CH1/CH2 meter and CH2 
indicator. 
 
 
 Slave (CH2) 
voltage level 
The CH2 meter reading shows 
the output voltage. In the above 
case, 20.0V. 
 Slave (CH2) 
current level 
The CH2 meter reading shows 
the output current. In the above 
case, 3.000A. 
    GPD-3303 Series User Manual 
32 
CH1/CH2 Tracking Parallel Mode 
 
Background / 
Connection 
Tracking parallel operation doubles the current 
capacity of the GPD-3303 series by internally 
connecting CH1 and CH2 in parallel and 
combining the output to a single channel. CH1 
controls the combined output. 
 
 
Output rating 
0 ~ 30V/0 ~ 6A 
 
1.  Press the PARA/INDEP key 
to activate the tracking 
parallel mode. The key LED 
turns on. 
 
 
2.  Connect the load to the CH1 +/− terminals. 
 
 
Note: this diagram shows non-European terminals.