SAFETY INSTRUCTIONS 
7 
 
•  To ensure fire protection, replace the fuse only 
with the specified type and rating. 
•  Disconnect the power cord before fuse 
replacement. 
•  Make sure the cause of fuse blowout is fixed 
before fuse replacement. 
Cleaning the 
GPD-3303 series
•  Disconnect the power cord before cleaning. 
•  Use a soft cloth dampened in a solution of mild 
detergent and water. Do not spray any liquid. 
•  Do not use chemicals or cleaners containing 
harsh products such as benzene, toluene, xylene, 
and acetone. 
Operation 
Environment 
•  Location: Indoor, no direct sunlight, dust free, 
almost non-conductive pollution (note below) 
•  Relative Humidity: < 80% 
•  Altitude: < 2000m 
•  Temperature: 0°C to 40°C 
 
(Pollution Degree) EN 61010-1:2001 specifies the pollution degrees 
and their requirements as follows. The GPD-3303 series falls under 
degree 2. 
Pollution refers to “addition of foreign matter, solid, liquid, or 
gaseous (ionized gases), that may produce a reduction of dielectric 
strength or surface resistivity”. 
•  Pollution degree 1: No pollution or only dry, non-conductive 
pollution occurs. The pollution has no influence. 
•  Pollution degree 2: Normally only non-conductive pollution 
occurs. Occasionally, however, a temporary conductivity caused 
by condensation must be expected. 
•  Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to 
condensation which is expected. In such conditions, equipment 
is normally protected against exposure to direct sunlight, 
precipitation, and full wind pressure, but neither temperature 
nor humidity is controlled. 
    GPD-3303 Series User Manual 
8 
Storage 
environment 
•  Location: Indoor 
•  Relative Humidity: < 70%  
•  Temperature: −10°C to 70°C 
Power cord for the United Kingdom 
When using the GPD-3303 series in the United Kingdom, make sure 
the power cord meets the following safety instructions. 
 
NOTE: This lead/appliance must only be wired by competent persons  
WARNING: THIS APPLIANCE MUST BE EARTHED 
IMPORTANT: The wires in this lead are coloured in accordance with the 
following code: 
Green/ Yellow:  Earth 
Blue: Neutral 
Brown: Live (Phase) 
 
As the colours of the wires in main leads may not correspond with the colours 
marking identified in your plug/appliance, proceed as follows: 
The wire which is coloured Green & Yellow must be connected to the Earth 
terminal marked with the letter E or by the earth symbol 
or coloured Green or 
Green & Yellow. 
The wire which is coloured Blue must be connected to the terminal which is 
marked with the letter N or coloured Blue or Black. 
The wire which is coloured Brown must be connected to the terminal marked 
with the letter L or P or coloured Brown or Red. 
If in doubt, consult the instructions provided with the equipment or contact the 
supplier. 
This cable/appliance should be protected by a suitably rated and approved HBC 
mains fuse: refer to the rating information on the equipment and/or user 
instructions for details. As a guide, cable of 0.75mm
2
 should be protected by a 3A 
or 5A fuse. Larger conductors would normally require 13A types, depending on 
the connection method used. 
Any moulded mains connector that requires removal /replacement must be 
destroyed by removal of any fuse & fuse carrier and disposed of immediately, as 
a plug with bared wires is hazardous if a engaged in live socket. Any re-wiring 
must be carried out in accordance with the information detailed on this label.