8
firewall http activex-blocking acl
Syntax
firewall http activex-blocking acl acl-number
undo firewall http activex-blocking acl
View
System view
Default level
2: System level
Parameters
acl-number: ACL number, in the range 2000 to 3999.
Description
Use the firewall http activex-blocking acl command to specify an ACL for ActiveX blocking.
Use the undo firewall http activex-blocking acl command to cancel the configuration.
By default, no ACL is specified for ActiveX blocking.
After the command takes effect, all Web requests containing any suffix keywords in the ActiveX blocking
suffix list will be processed according to the ACL.
You can specify multiple ACLs for ActiveX blocking, but only the last one takes effect.
You can specify a non-existing ACL, but ActiveX blocking based on the ACL takes effect only after you
create and configure the ACL correctly.
Related commands: display firewall http activex-blocking.
Examples
# Specify the ACL for ActiveX blocking as ACL 2003.
<Sysname> system-view
[Sysname] firewall http activex-blocking acl 2003
firewall http activex-blocking enable
Syntax
firewall http activex-blocking enable
undo firewall http activex-blocking enable
View
System view
Default level
2: System level
Parameters
None

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C SecPath Series and is the answer not in the manual?

H3C SecPath Series Specifications

General IconGeneral
CategoryFirewall
WeightVaries by model
ModelSecPath Series
ThroughputVaries by model
Concurrent SessionsVaries by model
VPN SupportYes
High AvailabilityYes
InterfacesVaries by model
Application IdentificationYes
Intrusion Prevention System (IPS)Yes
VPN ThroughputVaries by model
New Sessions Per SecondVaries by model
Power SupplyVaries by model
DimensionsVaries by model
Operating TemperatureVaries by model
Storage TemperatureVaries by model
Humidity5% to 95% (non-condensing)
CertificationsVaries by model

Related product manuals