33
6. On the screen as shown in Figure 58, select the RAID array you want to view and press Enter
to view detailed information about the RAID array (including RAID array name, level, and drive
information).
Figure 58 Selecting the target RAID array
Configuring hot spare drives
In legacy mode, if a hot spare drive is configured for a RAID array, the hot spare drive will not take
effect on other RAID arrays. To avoid this problem, configure all RAID arrays and then add hot
spare drives.
To configure a hot spare drive:
1. On the storage controller configuration screen as shown in Figure 59, select Array
Configuration and press Enter.
Figure 59 Storage controller configuration screen
2. On the screen as shown in Figure 60, select Manage Arrays and press Enter.