96-8000 73
MAINTENANCE
June 1999
2.1 TSC MAINTENANCE
îš• Check dirt indicator on 100 micron filter with TSC system running and no tool in the spindle. Change
element when the indicator reaches the red zone.
îš• On newer machines, clean pump intake filter when indicator is in red zone. Reset indicator with button.
All intake filters can be cleaned with a wire brush.
îš• After changing or cleaning filter elements, run TSC system with no tool in spindle for at least one
minute to prime system.
Figure 2-1. TSC coolant pump assembly. Figure 2-2. Cleaning the intake filter.
To clean the filter:
Turn off the coolant pump.
Remove the filter.
Clean and reinstall filter.