EasyManua.ls Logo

Hach Sigma 1600 - Page 28

Hach Sigma 1600
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 28
Sampler Programming Options
6507programming.fm
Section 3
Example 3: You want to collect 96 samples over a 24-hour period on a 4–20
mA flow proportional basis.
Average Flow Rate = 0.52 mgd (average flow rate over the 24-hour period)
Maximum Flow Rate=2mgd
a = 1440 minutes
1. Calculate Q.
2. Calculate t.
3. Multiply Q x t.
Therefore, the value entered for INTV=____CNTS is 4.
Example 4: You want to collect 32 samples over an 8-hour period.
Average Flow Rate = 70 gpm (average flow rate over the 8-hour period)
Maximum Flow Rate = 210 gpm
a = 480 minutes
1. Calculate Q.
2. Calculate t.
3. Multiply Q x t.
Therefore, the value entered for INTV=____CNTS is 5.
Example 5: It is desired to collect 30 samples over a 2-day period.
Average Flow Rate = 0.25 cfs (average flow rate over the 48-hour period)
Maximum Flow Rate=1cfs
a = 2,880 minutes
1. Calculate Q.
2. Calculate t.
3. Multiply Q x t.
Therefore, the value entered for INTV=____CNTS is 24.
Q
Average Flow Rate
Maximum Flow Rate
------------------------------------------------------
0.52 mgd
2.0 mgd
------------------------ - 0.26 mgd===
t
a
n
---
1440 min
96 samples
------------------------------ - 15 min/sample== =
0.26 mgd 15 min/sample× 3.9=
Q
Average Flow Rate
Maximum Flow Rate
------------------------------------------------------
70 gpm
210 gpm
----------------------- 0.33 gpm===
t
a
n
---
480 min
32 samples
------------------------------ - 15 min/sample== =
0.33 mgd 15 min/sample× 4.95=
Q
Average Flow Rate
Maximum Flow Rate
------------------------------------------------------
0.25 cfs
1 cfs
-------------------- - 0.25 cfs===
t
a
n
---
2,880 min
30 samples
------------------------------ - 96 min/sample== =
0.25 cfs 96 min/sample× 24=

Related product manuals