EasyManua.ls Logo

Haier GE AZ45E07DABW5 - Tools Required for Service; System Pressure Guidelines

Haier GE AZ45E07DABW5
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 7 –
System Pressures
Technicians with R-22 experience will need to become familiar working with high and
low side pressures that are much higher when using R-410A. A typical R-22 system
operates normally with a high side pressure of approximately 260 psi @ 120°F
condensing temperature and a low side pressure of approximately76 psi @ 45°F
evaporator saturation temperature.
A normally operating R-410A system with the same condensing temperature of
120°F and 45°F evaporator saturation temperature will have a high side pressure of
approximately 500 psi and a low side pressure of approximately 150 psi.
5/16-in. socket or drive
1/4-in. socket or drive: Ground screws and control assembly use 1/4-in. machine thread screws
3/8-in. socket or drive: For outdoor fan blade removal
4-mm Allen wrench: For indoor fan blade removal
Volt Ohm Meter
Amp probe
Needlepoint meter leads
Sealed system and R-410A recovery equipment
Thermal paste (Part #: WX5X8927)
Extension needed for condenser shroud screws
Tools Required
Caution