ELEKTRA 2500 HAMTRONIX
14
TROUBLESHOOTING
In case of malfunction, perform a Full reset so that the values programmed by the manufacturer are reestablished.
In this way all options of the functions return to the default values. It can be performed in three different ways:
1) Over the air, using a function 37: Enter: 123437#
2) Over the air, using the master password. Enter: NNNN123#
Where NNNN is a 4-digit master password for full reset from the back cover If the master password is 6986,
the command would be: 6986123#
Note: The Master password cannot be changed by the user, so keep that password confidential. This
command is not available if the controller is running in Super User mode (function 42).
3) On the controller board, using the multifunction button: Switch off the controller by opening the SW1
switch; keep the multifunction button pressed; turn on the SW1 switch (the green RX1 LED will light); wait
for it to flash (up to 20s) and then release the button. An open squelch noise followed by the startup melody
will be transmitted and all functions will return to their default values.
Note: The recorded messages and CW programming are not affected by any of the reset methods.
If the problem persists, contact technical support.
ACCESSORIES
7” Mini rack (Motorola) box
TED300 Encoder / Decoder CTCSS module
SSM350 Super Squelch Module
For more details on these accessories visit www.hamtronix.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hamtronix ELEKTRA 2500 and is the answer not in the manual?

Hamtronix ELEKTRA 2500 Specifications

General IconGeneral
BrandHamtronix
ModelELEKTRA 2500
CategoryController
LanguageEnglish