36 - RESET
Restart the microcontroller with user programmed values. A melody is heard to indicate a successful reset. Have the
same effect as power up.
Ex: 123436#
Note: The voice message and CW programming are not affected.
37 – REMOTE FULL RESET
Restart the microcontroller and all functions with default values.
Ex: 123437#
Note: The voice message and CW programming are not affected.
38 – VOICE MESSAGE LOCK (Default =1)
This is a security measure to protect the voice message from being erased by mistake. To be able to record a voice
message or use the Simplex Repeater function, this function must be disabled.
39 – MULT-FUNCTION BUTTON (Default = 2)
Determine the action of button S1.
Starts message 1 playback
COR simulation (acts like a REC button after function 19 to record a message)
Drops transmitter (Useful when checking for duplexer desense)
40 – VOICE MESSAGE DURATION (Default = 1)
41 – VOICE ID PRIORITY (Default = 0)
When repeater is busy, and the ID time is up or the voice is playing back and a signal is received, the voice will be
replaced by CW ID. If this option is enabled, the voice message will not be replaced.
42 – SUPER USER MODE (Default = 0)
If enabled, the password will not be required. Just enter the function and option.
Note: The Master Reset is not available in this mode.
43 – COURTESY TONE EDITOR (Default=611 611 61)
You can create your own exclusive courtesy tone. The courtesy tone can be composed by 3 tones and you can
control the interval, duration and frequency of each one. This function acts on the simple tone (Function 06-1).
[F][D][I] [F][D][I] [F][D]#
F=Frequency, D=Duration e I=Interval
Try the following combinations: 830 330 62, 230 430 62 and 722 742 00 (CW letter A).
To enter the first example, press: 1234 43 # 830 330 62#
Note: Zero duration tone will not be transmitted.