[文件標題] [日期]
13
Vol. 1.2 © 2020 Hanbell Precise Machinery Co., Ltd.
All rights reserved
Remark:1. IGV should be fully opened before start up. When HGBP opened before stop,please keep
IGV fully opened.
2. IGV operating range is 20%~100%.
3. Actuator signal feedback window:
Figure 3.2 OPEN Figure 3.3 SHUT
3.2 Vane actuator control
3.2.1 Actuator data
RATED POWER
1Phase, AC 220V±10%(50/60Hz)
1Phase, AC 110V±10%(50/60Hz)
INPUT SIGNAL
4~20mA‧DC;1~5V‧DC
OUTPUT SIGNAL
4~20mA‧DC
OUTPUT TORQUE
49N‧m(5kgf‧m)
OPERATION SPEED
15sec(50Hz);12.5 sec(60Hz)
TRAVEL ANGLE 0~90°
RATED OPERATION TIME Continuous (100%)
RESOLUTION Over 1/250
DEAD ZONE Max. 0.5%
PROTECTION Motor thermal protector (120ºC)
AMBIENT TEMPERATURE Ambient temperature within: -25~55ºC
RATED CURRENT
0.4A(220V);0.7A(110V)
MOTOR 20W
INSULATION GRADE Class E
INSULATION RESISTANCE Between power terminal – case : 500V·DC / 100MΩ
WITHSTAND VOLTAGE Between power terminal – case : 1500V·AC / 1 minute
WIRE INLET
G1/2×2
ENCLOSURE PROTECTION
NEMA-4X (IP-66)
WEIGHT
4.5kg
Table 3.1 Actuator data
Note:When operating at ambient temperature under 0℃, optional space heater is required to keep the
actuator inside dry. Otherwise, moisture may condense under low temperature and high humidity or
parts may shrink at low temperature.