16
ELECTRICAL SCHEMATIC
Models 1750, 2000 and 2500
Sheet 1 of 2
PLEASE NOTE:
FOR OPERATION 380-400VAC/3PH/50HZ,
MOVE PRIMARY TO 400VAC TAP.
02
A
04
06
08
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
66
68
B C D E F G H J K L M N P Q
L3
-Q00
-K62
-F11
M
L1-1
L2-1
L3-1
L1-1A
L2-1A
L3-1A
COMPRESSOR
460 VAC, 3 PH
Models 1750, 2000: 9 HP, 15.7 RLA
Model 2500: 10.5 HP, 19.3 RLA
TB1-1
TB1-2
TB1-3
TB1-PE
TB1-19
TB1-20
L2
L1
2.8-4A
-K43
-F13
M
L1-3
L2-3
L3-3
L1-3A
L2-3A
L3-3A
FAN 1
1.05 KW
460 VAC
1.8 RLA
TB1-7
TB1-9
TB1-11
TB1-PE
HEATER
27 W, 460 VAC
0.06A
-K62
1A
-F22A
-F22B
-F22C
L1-5
L3-5
L1-5
L2-5
40A
-F22
**MOUNTED
ON -T22
M
FAN 2
1.05 KW
460 VAC
1.8 RLA
TB1-13
TB1-15
TB1-17
TB1-PE
(10 AWG)
(12 AWG)
(1O AWG)(12 AWG)
-K45
L1-4A
L2-4A
L3-4A
14-20A
1A
1A
L1-5A
Models 1750, 2000: SET @ 15.7A
Model 2500: SET @ 19.3A
(SET @ 3.6A)
TB1-PE
FU22.1
TB2-1
5A
FU22
SHT#2 4B
SHT#2 4N
24V
120V
460V
400V
230V
208V
COM
FU22.2
N
-T22
24/120 VAC SECONDARY
208/230/400/460 VAC PRIMARY
100VA
ELECTRICAL SUPPLY
480VAC/3PH/60HZ/GND
OR
380-400VAC/3PH/50HZ/GND