EasyManuals Logo

HANKISON HPRplus HPRP1000 User Manual

Default Icon
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
18
ELECTRICAL SCHEMATIC
Model 3000
Sheet 1 of 2
PLEASE NOTE:
FOR OPERATION 380-400VAC/3PH/50HZ,
MOVE PRIMARY TO 400VAC TAP.
ELECTRICAL SUPPLY
480VAC/3PH/60HZ/GND
OR
380-400VAC/3PH/50HZ/GND
TB1-PE
02
A
04
06
08
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
66
68
B C D E F G H J K L M N P Q
L3
-Q00
22-32A
-K62
-F11
M
L1-1
L2-1
L3-1
L1-1A
L2-1A
L3-1A
COMPRESSOR
460 VAC, 3PH
13 HP, 25.7 RLA
TB1-1
TB1-2
TB1-3
TB1-PE
TB1-19
TB1-20
L2
L1
5.5-8A
-K43
-F13
M
L1-3
L2-3
L3-3
L1-3A
L2-3A
L3-3A
FAN 1
1.05 KW
460 VAC
1.8 RLA
TB1-7
TB1-9
TB1-11
TB1-PE
HEATER
27 W
460 VAC
0.06A
-K62
1A
1A
1A
-F22A
-F22B
-F22C
L1-5
L3-5
L1-5
L2-5
60A
-F22
**MOUNTED
ON -T22
M
FAN 3
1.05 KW
460 VAC
1.8 RLA
(10 AWG)
(12 AWG)
(8 AWG)
(12 AWG)
-K45
M
L1-4A
L2-4A
L3-43A
FAN 2
1.05 KW
460 VAC
1.8 RLA
TB1-13
TB1-15
TB1-17
TB1-PE
M
FAN 4
1.05 KW
460 VAC
1.8 RLA
(SET @ 25.7A)
(SET @7.2A)
L1-5A
TB1-PE
FU22.1
TB2-1
5A
FU22
SHT#2 4B
SHT#2 4N
24V
120V
460V
400V
230V
208V
COM
FU22.2
N
-T22
24/120 VAC SECONDARY
208/230/400/460 VAC PRIMARY
100VA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HANKISON HPRplus HPRP1000 and is the answer not in the manual?

HANKISON HPRplus HPRP1000 Specifications

General IconGeneral
BrandHANKISON
ModelHPRplus HPRP1000
CategoryDehumidifier
LanguageEnglish

Related product manuals