Hanna Instruments HI98194 User Manual

Hanna Instruments HI98194
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HI98194,
HI98195, HI98196
Multiparameter Meters
pH/mV, ORP, EC, TDS, Resistivity,
Salinity, Seawater σ, Dissolved
Oxygen, Atmospheric Pressure
and Temperature
INSTRUCTION MANUAL

Other manuals for Hanna Instruments HI98194

Question and Answer IconNeed help?

Do you have a question about the Hanna Instruments HI98194 and is the answer not in the manual?

Hanna Instruments HI98194 Specifications

General IconGeneral
ModelHI98194
pH Range-2.00 to 20.00 pH
ORP Resolution0.1 mV
Temperature Resolution0.1 °C
Conductivity Accuracy±1% of reading
TDS Accuracy±1% of reading
Resistivity Range0.00 to 100.0 MΩ·cm
Salinity Resolution0.01 ppt
Salinity Accuracy±1% of reading
PC ConnectivityUSB
GLPYes
IP RatingIP67
CategoryWater Quality Meters
TypeMultiparameter Meter
pH Resolution0.01 pH
pH Accuracy±0.01 pH
ORP Range±2000.0 mV
Temperature Range-5.0 to 105.0 °C
Temperature Accuracy±0.2 °C
Conductivity Resolution0.001 mS/cm
Resistivity Resolution0.001 MΩ·cm
Salinity Range0.00 to 70.00 ppt
Seawater Range0.0 to 70.0 ppt
Atmospheric Pressure Range450 to 850 mmHg
Atmospheric Pressure Accuracy±3 mmHg
ISE Range±2000.0 mV
CalibrationUp to 5 points
DisplayGraphic LCD with backlight
Logging TypeManual or automatic
Power Supply4 x AA batteries or adapter
Auto-offUser selectable
Environment0 to 50 °C, 0 to 100% RH
Dimensions185 x 93 x 35.5 mm
Weight400 g

Summary

General Description

Display and Keyboard Description

Chapter 2: Quick Start

Sensor and Probe Installation

Instructions for connecting sensors and probes to the HI9819X meter.

Basic Operation

Chapter 3: Specifications

Temperature Specifications

Details on the meter's temperature measurement range, resolution, accuracy, and calibration.

Conductivity Specifications

Meter Specifications

Probe Specifications

Sensor Specifications

Sensor Preparation and Activation

Sensor Installation

Meter Initialization

Measurement Mode

Parameter Coefficients

Quick Calibration

pH Calibration

pH Calibration Error Messages

Relative mV Calibration

Dissolved Oxygen Calibration

Conductivity Calibration

Temperature Calibration

Chapter 8: System Setup

Atmospheric Pressure Calibration

Steps for user calibration or restoring factory calibration for atmospheric pressure.

Meter Setup

Meter Setup (Continued)

GLP Data

GLP Data (ORP, DO, Conductivity)

Logging Menu Structure

Logging on Meter

Details on organizing and storing logged data in lots on the meter.

Log Recall

Log Notes and Remarks

Chapter 11: PC Connection Mode

Software Installation and Meter to PC Connection

Instructions for installing software and connecting the meter to a PC for data transfer.

Chapter 12: Troubleshooting / Error Messages

Troubleshooting and Error Messages

Common messages and error codes for troubleshooting meter issues.

Appendix A: Probe Maintenance

Appendix B: Probe Deployment

Recommendations for Users