Haskris R1600 User Manual

Default Icon
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
[Type text]
INSTRUCTION
M
ANUAL
For the
Installation, Start-up,
Operation and Maintenance
of your Haskris System.
Question and Answer IconNeed help?

Do you have a question about the Haskris R1600 and is the answer not in the manual?

Haskris R1600 Specifications

General IconGeneral
Cooling Capacity1600 W
Temperature Range5°C to 35°C
RefrigerantR134a
Voltage115 VAC or 230 VAC
Compressor TypeHermetic
Reservoir Capacity5.7 liters (1.5 gallons)
Power Requirements115 VAC, 60 Hz, 15 A or 230 VAC, 50 Hz, 8 A

Summary

Section 1: General Information

1.3 Installation Support (Haskris Co.)

Contact information and support channels for installation questions and issues with Haskris Co.

1.4 After Installation and Service Support (HMSA)

Contact information for Hitachi Medical Systems America (HMSA) for support and spare parts.

Section 2: Installation

2.5 Electrical Requirements

Information on power requirements, wiring diagrams, and recommendations for electrical installation.

2.7 Install Checklist

Checklist requirements that must be completed and faxed to Haskris before scheduling a 'No Load' Start-Up.

Section 3: Start-Up

3.1 Remove Liquid Refrigerant Prior to Compressor Start Up

Instructions to energize crankcase heaters 12 hours before start-up to evaporate liquid refrigerant.

3.2 No Load Start Up

Detailed steps for performing a 'No Load' start-up, requiring a Haskris authorized representative.

3.3 Full Load System Check

Procedure for conducting a 'Full Load' system check, requiring coordination with HMSA and a Haskris representative.

Section 4: Operating Features & Functions

4.1 Temperature Control

Details on the factory pre-set glycol solution temperature and allowable adjustments.

4.2 Water Pressure Bypass/Relief Valve

Explanation of the bypass/relief valve's function in modulating water pressure and its two basic functions.

4.4 High and Low Refrigerant Pressure Controls

Description of refrigerant pressure controls that prevent compressors from operating at unsafe pressures.

Section 5: Maintenance Recommendations

5.1.4 Glycol Change

Recommendation for changing the entire glycol solution based on pH or other factors.

Haskris Model R1600 Install Checklist

Haskris Model R1600 No Load Start-Up Checklist

Haskris Model R1600 Full Load System Check

Haskris Model R1600 Preventative Maintenance (PM)

PM System Check

Steps to be performed by a Haskris Authorized Representative for PM system check.

After Installation and Service Support (HMSA)