65 4000637120 E 06.19 USA / GB
C
- Pre-operation inspection
45XA - HLA16PX - 55XA - HLA19PX
4.4 - AUTOMATIC ENGINE CUT-OUT
The engine automatically cuts out in the following conditions :
• The alternator is not functioning.
• Engine temperature is too high.
• Oil pressure is too low.
• The E-stop(s) is (are) pushed in.
• The machine is switched off.
4.5 - OVERLOAD SENSING SYSTEM (IF EQUIPPED)
If the platform load exceeds the maximum allowed load, no movement is possible from the 2
control boxes.
At ground and platform control boxes a buzzer sounds and an indicator light warns the
operator
To return the machine to normal operation remove weight from the platform until the load is
below the maximum allowed load.
Daily check that the LED's illuminate when the machine is switched on :
• Verify that the Overload system is active : Refer to Indicators ( 6 ) at ground and ( 30 ) at
platform.
• Verify that the buzzers are functioning : Refer to Buzzers test
A periodic inspection of this device must be performed according to the recommendation in
Maintenance Schedule.