EasyManuals Logo

Hayward Pro Logic Installation Manual

Hayward Pro Logic
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Gall
n
s
a
n
d
(
L
i
t
e
r
s
)
o
f
P
o
o
l
/
S
p
a
w
a
t
e
r
12,000 14,000 16,000
1
8
,
0
0
0
2
0
,
0
0
0
2
2
,
0
0
0
3
2
,
0
0
0
2
4
,
0
0
0
3
4
,
0
0
0
2
6
,
0
0
0
3
6
,
0
0
0
2
8
,
0
0
0
3
8
,
0
0
0
3
0
,
0
0
0
4
0
,
0
0
0
Current salt
level
(45000) (52,500) (60,000)
(
6
7
,
5
0
0
)
(
7
5
,
0
0
0
)
(
8
2
,
5
0
0
)
(
1
2
0
,
0
0
0
)
(
9
0
,
0
0
0
)
(
1
2
7
,
5
0
0
)
(
9
7
,
5
0
0
)
(
1
3
5
,
0
0
0
)
(
1
0
5
,
0
0
0
)
(
1
4
2
,
5
0
0
)
(
1
1
2
,
5
0
0
)
(
1
5
0
,
0
0
0
)
ppm
0
320
(145)
373
(170)
427
(194)
4
8
0
(
2
1
8
)
(242)
587 854
(267) (388)
640 907
(291) (412)
693 960
(315) (436)
747
(339) (4
6
0
)
800
1
0
6
7
(364)
(
4
8
4
)
200
300
(136)
350
(159)
400
(182)
450
(205)
500
(227)
550 800
(250)
(363)
600 850
(273) (385)
650 900
(295) (408)
700 9
5
0
(318) (4
3
0
)
750
1
0
0
0
(341)
(
4
5
3
)
400
280
(127)
327
(148)
373
(170)
420
(191)
467
(212)
513 747
(233) (339)
560 793
(255) (360)
607 840
(276) (382)
653 8
8
7
(297) (4
0
3
)
700
9
3
3
(318)
(
4
2
4
)
600
260
(118)
303
(138)
347
(158)
390
(177)
433
(197)
477 693
(217) (317)
520 737
(236) (337)
563 780
(256) (358)
607 8
2
3
(276) (3
7
8
)
650
8
6
7
(297)
(
3
9
8
)
800
240
(109)
280
(127)
320
(145)
360
(164)
400
(182)
440 640
(200) (291)
480 680
(218)
(310)
520 720
(236) (328)
560 76
0
(255) (3
4
6
)
600
8
0
0
(273)
(
3
6
4
)
1000
220
(100)
257
(117)
293
(133)
330
(150)
367
(167)
403 587
(183) (267)
440 623
(200) (283)
477 660
(217) (300)
513 69
7
(233) (3
1
7
)
550
7
3
3
(250)
(
3
3
3
)
1200
200
(91)
233
(106)
267
(121)
300
(136)
333
(152)
367 533
(167) (243)
400 567
(182) (258)
433 600
(197) (274)
467 63
3
(212) (2
8
9
)
500
6
6
7
(227)
(
3
0
4
)
1400
180
(82)
210
(95)
240
(109)
270
(123)
300
(136)
330 480
(150) (218)
360 510
(164) (232)
390 540
(177) ( 246)
420 57
0
(191) (2
5
9
)
450
6
0
0
(205)
(
2
6
3
)
1600
160
(73)
187
(85)
213
(97)
240
(109)
267
(121)
293 427
(133)
(195)
320 453
(145) (207)
347 480
(158) (219)
373 50
7
(170) (2
3
1
)
400
5
3
3
(182)
(
2
4
3
)
1800
140
(64)
163
(74)
187
(85)
210
(95)
233
(106)
257 373
(117) (169)
280 397
(127) (180)
303 420
(138) (190)
327 44
3
(148) (20
1
)
350
4
6
7
(159)
(
2
1
1
)
2000
120
100
80
60
20
40
(55)
(45)
(36)
(27)
(9)
(18)
140
117
23
47
(64)
(53)
(11)
(21)
160
133
27
53
(73)
(61)
(12)
(24)
180
150
30
60
(82)
(68)
(14)
(27)
200
167
33
67
(91)
(76)
(15)
(30)
220 320
183 267
37 53
73 107
(100) (145)
(83) (121)
(17) (24)
(33) (48)
240
340
200 283
40
57
80 113
(109) (154)
(91) (129)
(18) (26)
(36) (51)
260 360
217 300
43 60
87 120
(118) (163)
(98) (137)
(20) (27)
(39) (54)
280 38
0
233 31
7
47
6
3
93
1
2
7
(127) (17
2
)
(106) (1
4
4
)
(21) (2
9
)
(42) (5
7
)
300
4
0
0
250
3
3
3
50
6
7
100
1
3
3
(136)
(
1
8
1
)
(114)
(
1
5
2
)
(23)
(
3
0
)
(45)
(
6
0
)
(32)
80
(36)
90
(41)
100
(45)
1
1
0
1
6
0
(
5
0
)
(
7
3
)
1
2
0
1
7
0
(
5
5
)
(
7
7
)
1
3
0
1
8
0
(
5
9
)
(
8
1
)
1
4
0
1
9
0
(
6
4
)
(
8
6
)
1
5
0
2
0
0
(
6
8
)
(
9
0
)
93
(42)
107
(48)
120
(55)
133
(61)
1
4
7
2
1
3
(
6
7
)
(
9
8
)
1
6
0
2
2
7
(
7
3
)
(
1
0
4
)
1
7
3
2
4
0
(
7
9
)
(
1
1
0
)
1
8
7
2
5
3
(
8
5
)
(
1
1
7
)
2
0
0
2
6
7
(
9
1
)
(
1
2
3
)
2200
3000
2800
2400
3200
Ideal Ideal Ideal Ideal Ideal
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
2600
3400
OK
OK
OK
OK
OK OK OK
O
K
O
K
O
K
O
K
O
K
O
K
O
K
O
K
O
K
O
K
P
O
U
N
D
S
a
n
d
(
K
g
)
O
F
S
A
L
T
N
E
E
D
E
D
F
O
R
3
2
0
0
P
P
M
3600+
Dilute Dilute Dilu
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
10,000
8,000
(37,500)
213
267
(97)
(121)
200 250
(91) (114)
187 233
(85)
(106)
173
217
(79)
(98)
160 200
(73)
(91)
147 183
(67) (83)
133 167
(61) (76)
120 150
(55) (68)
107 133
(48) (61)
93 117
(42) (53)
80 100
67 83
53
67
40 50
13 17
27 33
(36) (45)
(30) (38)
(24) (30)
(18) (23)
(6) (8)
(12)
(15)
Ideal
Ideal
Dilute
Dilute
(30,000)
4
Salt (When using optional chlorinator function)
Salt Level
Use the chart below to determine how much salt in pounds or (Kgs) should be added to reach the recommended
levels. Use the equations on the following page (measurements are in feet/gallons and meters/liters) if pool size is
unknown.
The operating salt level is between 2700-3400 PPM (parts per million) with 3200 PPM being optimal. Before
adding any salt, test the salt level. This is especially important for retrofit installation to older pools where all of the
chlorine added to the pool over time is ending up as salt. If the level is low, determine the number of gallons in the
pool and add salt according to the chart below. A low salt level will reduce the efficiency of the sanitization and
result in low chlorine production. A high salt level can cause the Pro Logic to stop chlorinating. The salt in your
pool/spa is constantly recycled and the loss of salt throughout the swimming season should be minimal. This loss is
due primarily to the addition of water because of splashing, backwashing, or draining (because of rain). Salt is not
lost due to evaporation.
39
Digital Spa Config.
+ to view/change
Digital A, Button 1
Pool/Spa
Digital A, Setpoint
Heater1
Select Digital Spa
A
Push to access the Digital Spa Side Remote options
Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, Valve3,
Valve4, and all available Aux outputs
Rotates between heaters that are enabled
Rotates between all available remotes
Move to previous/next configuration menu
Move to previous/next menu item
Move to previous menu item or next configuration menu
Move to next menu item
if AQL-SS-D is connected
Select Digital Spa
This menu only appears if more than one AQL-SS-D is detected at power up. Select which of the
available remote controls (A, B or C) is to be configured.
Digital A, Button 1
This menu allows the user to map each button of the AQL-SS-D to one of the standard Pro Logic
functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3 - Lights, Button
4 - Heater1, Button 5 - Valve3, Button 6 - Valve4, Button 7 - Aux1 and Button 8 - Aux2.
Digital A, Setpoint
If more than one heater is installed, select the spa heater you wish to control. If no heaters are
installed, “Heaters Disabled” will be displayed.
Remote Menus
Enabled
Toggle between Enabled (default) and Disabled Remote Menus
Move to previous/next configuration menu
This feature will prevent unauthorized access to the Settings, Timers, and Configuration menus from
any of the Pro Logic’s remote display/keypads. When disabled, the remote display/keypads will only
show the default menu and allow on/off control via the pushbuttons. Note that the function of the Pro
Logic’s built-in display/keypad is unchanged by this selection. Once disabled, the only way to enable
“Remote Menus” is to use the local display/keypad.
All Timeclocks
7-day
Move to previous/next configuration menu
Toggle between 7-day (default) and Weekend/Weekday time options
This selection affects ALL of the timeclock logic in the Pro Logic. If “7-day” is selected, each
timeclock will have one set of turn-on/turn-off settings that operate every day of the week. If “Weekend/
Weekdays” option is selected then the user can enter one set of turn-on/turn-off times for the weekend
(fixed as Saturday/Sunday) and another set of turn-on/turn-off times for weekdays (Monday through
Friday).
Time Format
12 hour AM/PM
Units
ºF and PPM
Move to previous/next configuration menu
Move to previous/next configuration menu
Toggle between 12 hour AM/PM (default) and 24 hour time format options
Toggle between ºF and PPM (default) and ºC and g/L (Metric) options

Other manuals for Hayward Pro Logic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward Pro Logic and is the answer not in the manual?

Hayward Pro Logic Specifications

General IconGeneral
TypeAutomation Controller
ExpandabilityYes
DisplayLCD
Housing MaterialPlastic
ConnectivityWired and Wireless Options
Voltage120V/240V
Beam AngleN/A (Controller, not a light)
Installation TypeWall-mounted
Control CompatibilityHayward Equipment
Salt ChlorinationOptional (with Salt Cell)

Related product manuals