32
4
Slide
a
#6
lockwasher
onto
the
screw
on
the
outside
of
the
chassis
at
FD.
“Use
a
6-32
nut
to
mount
the
toroid
coil
onto
the
chassis
at
FD.
Be
sure
to
orient
the
coil
so
the
center-tap
lead
is
in
the
posi-
tion
shown
in
the
Pictorial.
The
other
two
wires
may
exit
the
coil
in
positions
that
are
different
from
those
shown.
we
Cut
the
center-tap
toroid
coil
lead
to
4-1/4",
if
this
has
not
already
been
done.
If
the
center-
tap
lead
has
insulation,
remove
1/4”
of
the
insulation
from
the
end.
If
the
lead
does
not
have
insulation,
cut
a
4"
length
of
sleeving
and
slide
it
onto
the
lead.
Now
connect
the
lead
to
switch
SW1D
lug
12
(S-1).
Connect
the
longer
remaining
toroid
coil
lead
(if
the
leads
of
your
toroid
are
the
same
length,
use
either
lead)
to
switch
SWID
lug
11
(NS).
Cut
the
lead
as
necessary
to
reach
the
lug
and
remove
1/4"
of
insulation
from
its
end.
Connect
the
remaining
toroid
coil
lead
to
the
bare
wire
that
is
connected
between
switch
SWID
lug
1
and
SWIE
lug
1
(S-1).
Cut
the
lead
as
necessary
to
reach
the
lug
and
remove
1/4”
of
insulation
from
its
end.
RFC1:
Cut
both
leads
of
a
2.5
mH
RF
choke
to
1/2".
Then
connect
one
lead
to
switch
SW1D
lug
11
(NS).
Position
the
choke
as
shown
in
the
Pictorial.
Solder
the
other
choke
lead
to
the
switch
frame
in
the
indicated
area.
J
y
y
Heathkit
Cut
a
1-3/4"
medium
bare
wire.
Use
this
wire
in
the
next
step.
Refer
to
inset
drawing
#2
and
pass
one
end
of
the
1-3/4"
bare wire
through
switch
SWIC
lug
7
(both
lugs).
Leave
about
1”
of
wire
extending
through
the
lugs
(away
from
the
chassis).
Then
solder
the
other
end
of
the
bare
wire
to
the
switch
frame
in
the
indicated
area.
Solder
the
wire
to
both
lugs
at
SW1C
lug
7.
Refer
to
inset
drawing
#3
and
cut
a
long
#8
solder
lug
to
5/8".
Then
pass
the
narrow
end
of
the
solder
lug
through
switch
SWIE
lug
11
(both
lugs).
Solder
the
lug
to
both
switch
lugs.
INPUT
FILTER
CHECKOUT
Carefully
inspect
the
input
filter
chassis
for
the
following
most-
commonly-made
errors:
yf
Jd
Unsoldered
connections.
NOTE:
Lug
11
of
switch
SW1D
will
be
soldered
later.
Poor
solder
connections.
Protruding
leads
that
could touch
together,
the
chassis,
or
other
lugs
to
which
they
are
not
connected.
Protruding
leads
and
rotary
switch
solder
co-
nnections
that
could
touch
the
switch
moun-
ting
hardware.
This
completes
the
assembly
of
the
input
filter.
Shake
out
any
solder
globs
or
other
foreign
matter
which
may
be
lodged
in
the
wiring.
Then
set
the
filter
aside
until
it
is
called
for
ina
step.

Other manuals for Heathkit SB-1000

Related product manuals