74
Refer to:
• Checking for air leaks (Located in Air Leaks).
7. Q. Why am I experiencing an excess build up of creosote in the furnace?
A. You more than likely are introducing unwanted draft into the rebox. This may be caused by several
things, including a door ajar, ash auger tube cover loose, ipper assembly stuck. If your furnace
is in a location where wind may effect the pressure differential across the furnace, it could
cause draft to leak past the ipper.
Refer to:
• Creosote Build-up (Located in Trouble Shooting and Solutions).
8. Q. How do you change a door hose while the furnace is in operation?
A. Never change a door hose unless the furnace is cooled. Please refer to the rebox door hose
section in the manual for further details or contact your local dealer.
Refer to:
• Firebox Door Hoses and Elbows (Located in Firebox and Other Components).
9. Q. My furnace combustion blower continues to run but the fire will not burn until I open the
door?
A. Your ipper assembly is most likely stuck closed. Please refer to the combustion blower, ipper
assembly section in the manual for further details or contact your local dealer.
Refer to:
• Combustion Air Blower and Flipper Assembly (Located in Air Supply).
10. Q. Water is coming out of the rectangular top chimney flue?
A. Similar to the rebox, when your furnace is initially red up and also at times during normal
operation, the atmosphere inside the rebox and chimney ue will exceed the dew point causing
condensation.
Refer to:
• Furnace has excessive moisture in rebox (Located in Trouble Shooting and Solutions)
• Dew Point (Located in Safe Operating Guidelines).