CHAPTER 24
TROUBLESHOOTING AND SOLUTIONS
Main Principles to Remember
Enough Wood.
Enough Water.
Fans On – Air Must Get In.
Fans Off – Air Must Stay Out.
Water Temperature between 165 and 180 degrees Fahrenheit.
PROCEDURES ARE REFERENCED TO THIS HEATMOR™ “OPERATORS AND MAINTENANCE
MANUAL”
PROBLEM CAUSE SOLUTION PROCEDURE
Furnace Boils Draft ipper stuck open.
Remove blower and
ipper assembly.
Clean, lube or replace.
Refer to
Steps to “Maintain your Blower
and Flipper Assembly.”
Draft Flipper not closing
100 percent.
Remove blower and
ipper assembly.
Clean, lube or replace.
Refer to
Steps to “Maintain your Blower
and Flipper Assembly.”
Blower, Flipper Assembly
plate not tight.
Tighten wing nuts.
Refer to
Steps to “Maintain your Blower
and Flipper Assembly.”
Ashes holding ipper
open in air box(s).
Clean out ashes.
Refer to
“Air Box(s).”
Firebox door improperly
adjusted.
Adjust Firebox Door.
Refer to
“Firebox Door.”
Firebox door ajar, not
shut tight.
Close Fire Door Tight.
Refer to
“Firebox Door.”
Ash Auger tube not
sealed tight.
Close Tube Cover
Firmly.
Refer to
“Ash Auger Tube Cover Plate.”
Top ue cover plate not
sealed.
Tighten ½ inch nuts.
Refer to
“Top Rectangular Flue.”
Door gasket damaged. Replace Gasket.
Refer to
“Firebox Door Gasket.”