EasyManua.ls Logo

Heatmor 100 CSS - Page 86

Heatmor 100 CSS
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
81
Burning high surface
area wood (small pieces).
Add larger pieces
of wood.
Refer to
“Types of Wood.”
Air ow is not sufcient
for the type of fuel.
Check and clean fan
blades. Check and
clean ipper assembly.
Refer to
“Combustion Air Blowers /
Flipper Assemblies.”
Ashes in Air Box(s). Clean Air Box(s).
Refer to
“Air Box.”
Chimney Plugged. Clean Chimney.
Refer to
“Chimney Stub.”
Burning wet wood. Add dryer wood as fuel.
Refer to
“Types of Wood.”
Burning unseasoned
wood.
Add seasoned
wood to your fuel.
Refer to
“Types of Wood.”
Flue plugged. Clean Flue.
Refer to
“Top Rectangular Flue.”
Water temperature not
being held in the 160 to
180 degree range
Adjust setting.
Refer to
“Electrical (Water Temperature
Range Control).”
Thermometer
(temp gauge)
exceeds
212 degrees
Fahrenheit.
Furnace is not
boiling.
Low water level
Add water.
(Let Furnace cool rst)
Refer to
“Water Level Maintenance.”
Charcoal build-up
in rear of rebox.
Excessive ashes. Remove ashes.
Refer to
“Ash Management and Ash
Removal.”
Faulty back blower.
(400 DCSS ONLY)
Replace Blower.
Refer to
“Combustion Air Blowers /
Flipper Assemblies.”
Back blower has air ow
restriction. (400 DCSS
ONLY)
Clean Blower and Air
Box.
Refer to
“Combustion Air Blowers /
Flipper Assemblies,
Air Box(s).”
PROBLEM CAUSE SOLUTION PROCEDURE

Table of Contents

Related product manuals