Furnace pad has not
been raised above
ground level.
Raise pad.
Contact your
Local Dealer.
Draft fan has not been
turned off while loading.
Turn off fan before
loading.
Refer to
“Loading Wood into the
HEATMOR™.”
Losing Water
Furnace is boiling (could
happen when away,
sleeping or at work).
Add water. Complete a
full furnace check of all
systems.
Refer to
“Filling the Furnace Initially
with Water.”
Very slow leak
somewhere in the
system.
Check and tighten any
leaking ttings.
Contact your
Local Dealer.
Someone is taking hot
water from the system
when needed.
Add water.
Refer to
“Water Level Maintenance.”
Someone has
accidentally opened
a valve and not told
anyone.
Add water.
Refer to
“Water Level Maintenance.”
Leaking water line. Fix leak in water line.
Contact your
Local Dealer.
Bladder is leaking. Replace bladder. Refer to “Bladder.”
Door hoses are leaking. Replace door hoses.
Refer to
“Firebox Door Hoses and
Elbows.”
Bladder gate valve needs
adjusting.
Adjust and tighten
gate valve.
Refer to
“Bladder Gate Valve and
Bladder Hose.”
Hose clamps are leaking. Tighten hose clamps. Contact your
Local Dealer.
PROBLEM CAUSE SOLUTION PROCEDURE