HEIDENHAIN iTNC 530 Programming Station 19
1.1 Introduction
Differences in touch probe cycles concerning older software
versions of the iTNC 530
Meaning of the symbols used in the table:
– Parameter not available in this software version
þ Parameter or cycle available in this software version
x Cycle not available in this software version
Cycle
Additional
parameters
iTNC 530,
software version
340 422 340 420
4, Measuring in 3-D – x x
9, Calibrate TS length – þ x
400, Basic rotation Q305 – –
401, ROT of 2 holes Q305
Q402
Q337
–
–
–
–
–
–
402, ROT of 2 studs Q305
Q402
Q337
–
–
–
–
–
–
403, ROT about rotary axis Q337
Q305
Q380
–
–
–
–
–
–
404, Set basic rotation Q305 – –
408, Slot center ref pt – x x
409, Ridge center ref pt – x x
410, Datum inside rectangle Q303
Q381
Q382
Q383
Q384
Q333
–
–
–
–
–
–
–
–
–
–
–
–