December 2001 3 151
3.26.4 Cable Overview for TNC 426 M, TNC 430 M with HEIDENHAIN Nonregenerative Compact Inverter UE 2xxB - Basic Configuration
LE 410 M
LE 426 M
UM 111
UE 2xx
B
30m
15m
289 440-xx
VL
336 847-xx
X69
X51 ... X56/61
250 479-07 ... -16
325 816-xx
325 817-xx
244 005-xx
BC 120
313 037-02
40m
VL
263 955-xx
263 954-xx
25m
40m
VL
312 878-xx
VL
312 876-xx
340 300-xx
312 875-xx
1m
TE 420
313 038-01
BF 120
313 506-01
MB 420
293 757-xx
263 954-xx
VL
263 955-xx
X49 X43 X45
X46
X1 ... X6
X15 ... X20
X60
263 954-xx
40m
244 005-xx
X8/X9
X41/X42
290 110-xx
20m
290 109-xx
15m
336 376-xx
336 376-xx
30m
VL
340 302-xx
10m
60m
VL
323 897-xx
332 115-xx
VL
323 897-xx
332 115-xx
max.1m
20.07.2001
9m
309 783-xx
60m
310 199-xx
298 429-xx
298 430-xx
PW 210
51m
LC 181: 313 791-xx
LC 481: 332 790-xx
LC
LC 181: 313 791-xx
LC 481: 332 790-xx
LC
VL: Extension cable
 for separation points with connecting cable
 for extending existing connecting cable
Rotary encoder
for speed control
Motor power cable
see Motors data sheet
Terminal box
251 249 01
Encoders for
position control
37-pin male connector
315 650-07
15-pin male connector
315 650-03
Housing must be mounted
1 V
PP
1 V
PP
1 V
PP
(only TNC 426
M)
Analog output
PLC I / 0
Included with
visual display unit
Position inputs
Speed inputs
EnDat for speed and
position control
(only TNC 426
M)
Voltage controller 5 V
336 697-02
Voltage controller 5 V
336 697-01
Basic configuration
Compact inverter
1 V
PP
Siemens
EnDat interface

Table of Contents