6 514 HEIDENHAIN Technical Manual TNC 426, TNC 430
7
77
7 Calculate MP2421.x:
MP2421.x = <determined value> · 0.6:
7
77
7 Set this value and confirm it with the STORE MP2421.X soft key.
7
77
7 With the I FACTOR / P FACTOR soft key, select the I factor.
7
77
7 With the soft key, increase the I factor (MP2431.x) until you see one
overshoot but no undershoot.
7
77
7 Confirm this value with the STORE MP2431.X soft key.
7
77
7 Switch-off the machine to exit the I CONTROL mode.
7
77
7 Press END.
MP2421 at the oscillation limit
MP2431 optimum

Table of Contents