8 Control unit DC 6-00 ... 05
22 Digital Governor Basic System PANDAROS II
8 Control unit DC 6-00 ... 05
8.1 Specification
8.1.1 General
Supply voltage 12 V DC or 24 V DC
Min. voltage 9 V DC or 18 V DC
Max. voltage 33 V DC
Max. ripple voltage max. 10 % at 100 Hz
Maximum power rating max. 7 A, and
max. 11 A for max. 60 seconds
Permissible voltage dip at
maximum current consumption max. 10 % at control unit
Fuse protection of governor 12 A
Storing temperature -40°C +85°C
Operating temperature -40°C +80°C
Humidity up to 98% at 55°C
Dynamic strength max. 2 mm at 10 20 Hz,
max. 0,24 m/s at 21 63 Hz
max. 7 g at 64 2000 Hz
Shock 50 g, 11 ms- half-sine wave
Protection grade IP 00
Insulation resistance > 1 MOhm at 48 V DC
Weight approx. 0.5 kg
EMC directives 2004/108/EG
2004/104/EG
according to EMC standards: ISO 11452-2
ISO 7637-2 / -3
DIN EN 61000-6

Table of Contents