29
read the description on page 33, point 7; Congura-
tion of the remote input.
12
+12 V
Connect the +12 V power cable to the positive ter-
minal of the battery. Recommended cross section:
min. 16 mm² / AWG 6.
13
Line Output
Processed 2-channel pre-amplier output with a
maximum output voltage of 3 Volts for connect-
ing additional power ampliers. Please make
sure that you always turn on / o external ampli-
ers using the remote output (Rem. Out) of the
V TWELVE DSP MK2. Never directly control the
external amps by a signal from the ignition switch
of your car! Additionally this output will be turned
o when the “Power Save Mode” of the amplier is
active. The outputs can be assigned to any of the
inputs as desired using the DSP PC-Tool software.