31
Reg. step 1: The factory setting of the input
sensitivity (Highlevel 11.3 Volts; RCA / Cinch
2.8 Volts) of the V TWELVE DSP MK2 are ap-
propriate for the most common radios. As soon
as the connected signal source provides an
maximum input voltage of 14 Volts – for ex-
ample, if a factory installed amplier is used
as signal source – all four internal jumpers has
to be repositioned to the “High Voltage Range”
(Highlevel 8 - 32 Volts; RCA / Cinch 2 - 8 Volts).
To get access to the jumpers the device has to
be opened. Therefore dismantle the side panel
where the USB input is located by removing the
two Phillips and two Allen screws and pull out
the bottom plate sideways.
Now you have access to the jumpers.
J 3
J 4
J 1
J 2
Overview plug-in positions:
Jumper 1 (J 1): Channel A - D
Jumper 2 (J 2): Channel E - F
Jumper 3 (J 3): Channel G - J
Jumper 4 (J 4): Channel K - L
For repositioning a jumper simply pull it up-
wards and plug it into the desired plug position.
Make sure that the jumper is reinserted properly
and all pins are fully inserted.
If you are not sure regarding the signal sources
output voltage, please contact your HELIX spe-
cialist dealer.
Low Voltage Range jumper plug-in positions (by
default):
Value range: Highlevel 4 - 16 Volts
RCA / Cinch 1 - 4 Volts
J 1
J 2
J 3
J 4
High Voltage Range jumper plug-in positions
:
Value range: Highlevel 8 - 32 Volts
RCA / Cinch 2 - 8 Volts
J 1
J 2
J 3
J 4