Menu navigation and adjustment values
9
41
Term
Description
Unit
Overview Operation
modes
Selection operation modes:
▪ Heating OFF
The heating system is switched off
▪ Heating time mode:
Heating corresponds to the set heating time
▪ Durable heat:
Constant heat up to required set room temperature or to the
calculated feed flow target temperature
▪ Durable kneeling:
Always heat to the kneeling temperature or during the kneeling time
to the calculated flow must temperature
▪ Remote control mode:
Mode according to the setting of the remote control
Menu "Status"
Status 1
1 2
Flow temperature
Indicates the flow temperature of chosen heating circuit
°C
Back flow temperature
Indicates the back flow temperature of chosen heating circuit
°C
Outside temperature
Display of the actual outside temperature
°C
Room temperature
Setting up required room temperature (15-30).
°C
Room correction
The correction is a factor for influencing or correction of the flow must
temperature:
This value (-5 to +5) gets multiplied by 2 and added to the flow set
temperature
°C
Status 2
1 2
Switching temperature
Indicates the switching temperature (= average daytime temperature). In
general the switching temperature conduces to switch between winter set
temperature and summer set temperature.
°C
Heating circuit mixer
Indicates the state of the heating circuit mixer (OPEN/CLOSE)
-
Heating circuit pump
Indicates the state of the heating circuit pump (ON/OFF)
-
Screed days
Display of the respective screed day (only if screed drying is set)
-
Menu "Settings"
Settings 1
1 23
Operation modes
▪ OFF: The heating system is switched off
▪ Heating time mode: Heating corresponds to the set heating time
▪ Durable heat: Constant heat up to required set room temperature or to
the calculated feed flow target temperature.
▪ Durable kneeling: Always heat to the kneeling temperature or during
the kneeling time to the calculated flow must temperature.
▪ Flow fixed: During the set heating times the set flow fixed temperature
is kept constant.
▪ Remote control: Mode according to the setting of the remote control.
▪ Screed drying: Mode of screed drying. The operation of the screed
drying is described below
-