Maintenance schedule
11
83
step grate (front / back / upper / lower)
Procedure
Interval [h]
lubricant
Bearing lubricate (motor side)
3000
Mobilux EP 2/NLGI 2
Bearing lubricate (rocker lever)
6000 (or annual
maintenance)
High temperature grease LGHP 2/0.4
retighten hex-screw (motor side)
3000
-
retighten hex-screw
6000
-