Recable and run the utility again if necessary.
4. Power on the system and boot to the UEFI Shell.
eRMC cli> power on npar bootopt=uefishell
5. To confirm that there are no CRC errors or dropped lanes, run test upi again.
eRMC cli> test upi
6. Check the status of the system hardware.
eRMC cli> show health
eRMC cli> show complex
eRMC cli> show npar
eRMC cli> show cae
eRMC cli> show indict
eRMC cli> show deconfig
eRMC cli> show logs sel
7. Boot the operating system.
8. Verify that the memory configuration includes all memory.
linux# topology --nodes
linux# free
linux# top
9.
(Optional) Run olcmt for 15 minutes if it is available and time permits.
linux# olcmt -runtime 15
10.
To log the hardware status after replacing the part, run collect rcu.
RMC cli> collect rcu