24
SERVICE AND CALIBRATION
It is important that the case of Supercell is not damaged. Regularly check for defects such as
cracks, broken connectors, or damage that would allow water to enter the machine. If damage
is found, stop using the unit immediately and contact your distributor.
There are no user serviceable parts inside Supercell. It should be returned to authorized ser-
vice agent for repair and calibraon. WARNING: The removal of the lid by unauthorized per-
sons could result in electric shock or re.
Calibraon
Supercell is equipped with a Smart Calibraon feature that allows the unit to check that fusion
parameters are within specicaon before each fusion. This conrms that the output is correct
and can extend the service period of the equipment. It is, however, recommended that Super-
cell be returned to an authorized service agent every two years.
FAULT FINDING
During operaon, the welding processor monitors all aspects of its operaon. If a fault occurs,
then an error message will be shown.
0: Weld OK
No Fault, weld completed OK.
1: Stuck buon on start up
This fault shows when the power is rst switched on. Either the Stop, Start, or a keypad buon
is stuck in. Free the buon to clear the fault.
2: Output fault before weld start
This fault shows when the power is rst switched on. The unit will check the output terminals
to make sure no voltage is present when rst switched on. If this fault happens then the inter-
nal power relays have stuck in the closed posion. The unit will need to be returned for ser-
vice.
4: No calibraon
This fault happens when the unit has no calibraon. This will normally not show, and if the unit
has been calibrated, would be caused by a fault with the internal memory. Return the unit for
service.
7: Ambient temperature less than -4
o
F.
The unit has detected that the ambient temperature is very cold or the sensor has broken. If
the temperature is not below -4
o
F then the unit will need to be returned to a service agent for
repair.