System
Enable auto rebuild (default: Enabled)
When a physical drive fails, the controller will take the drive offline. Once you re-insert or
replace the disk, the controller will not automatically rebuild the array unless this option is
enabled.
Enable continue rebuilding on error (default: Enabled)
When enabled, the rebuilding process will ignore bad disk sectors and continue rebuilding until
completion. When the rebuild is finished, the data may be accessible but may also be
inconsistent, due to any bad sectors that were ignored during the procedure. If this option is
enabled, HighPoint recommends checking the event log periodically for bad sectors warnings.
Rebuild Priority (default: Medium)
You can specify the amount of system resources you want to dedicate to rebuilding the array.
There are 5 levels of priority [Lowest, Low, Medium, High, Highest].