Digital Series Light Controller User Manual
3
The control cable of the device and the power cable of the industrial light source must be
wired separately to avoid bundled wiring.
The power cable, data cable, signal cable, etc. of the device must be wired separately.
Make sure to ground them if the wiring groove is used to separate the wiring and the
wiring groove is metal.
During the wiring process, evaluate the wiring space reasonably, and do not pull the cables
hard, so as not to damage the electrical performance of the cables.
The unused cables of the device must be insulated.
To avoid the accumulation of static electricity, ensure that other equipment (such as
machines, internal components, etc.) and metal brackets on site are properly grounded.
During the installation and use of the device, high voltage leakage must be avoided.
Use a figure-eight bundle method if the device cable is too long.
When connecting the device and metal accessories, they must be connected firmly to
maintain good conductivity.
Use a shielded network cable to connect to the device. If you use a self-made network
cable, make sure that the shielding shell at the aviation head is well connected to the
aluminum foil or metal braid of the shielding cable.