Chapter 5 Device Sengs
You can also set the turnsle to passing mode and memory mode, pair the keyfob, inialize the
hardware, switching between RS-485
communicaon mode and RS-232 communicaon mode, and
view relay output NO/NC diagram by seng the DIP switch on the main control board.
• Normal Mode: The device will work properly.
• Passing Mode: There are 9 passing modes, including controlled
bi-direcon, controlled entrance
and prohibited exit, controlled entrance and free exit, free bi-direcon, free entrance and
controlled exit, free entrance and prohibited exit, prohibited bi-direcon, prohibited entrance
and free exit.
• Memory Mode: By default, the memory mode is enabled. When
mulple cards are presented
and authencated, it allows mulple persons passing through the lane. When it counts the
passing people number is equal to the card presented
mes, or no person passing through the
lane aer the last person passing, the barriers will be closed.
Note
You can also set the DIP switch on the main control board to control the entrance and exit
controlling type, keyfob pairing, etc. For details about the DIP switch value, see .
5.1 Pair Keyfob (Oponal)
Pair the remote control to the device through DIP switch to open/close the barrier remotely.
Before You Start
Ask our technique supports or sales and purchase the keyfob.
Steps
1. Power o the turnsle.
2. Set the No.4 switch of the 8-digit DIP Switch on the main control board to the ON side.
3. Power on the turnsle and it will enter the keyfob pairing mode.
4. Hold the Close buon for more than 10 seconds.
The keyfob's indicator of the will
ash twice if the pairing is completed.
5. Set the DIP switch as OFF (the number side), and reboot the turnsle to take eect.