DS-K1T671TM-3XF
Introduction -> Device Parameters
50,000 face capacity
50,000 M1 card capacity
100,000 event capacity
Temperature
measurement
Sensor
Vanadium Oxide uncooled sensor
Resolution
120
× 160
Frame rate
25 fps
Temperature range
30
°C to 45 °C
Temperature accuracy
±
0.5 °C, without black body calibration
Measuring distance
0.3 to 2.0 m
Other
Working voltage
12 VDC/2 A
Working temperature
0
°C to 50 °C
For temperature measurement: 10
°C to 35 °C
Working humidity
10 to 90% (No condensing)
Application
Indoor
Application environment
Indoor and windless environment use only