Before You Start
On the link
ed devices network conguraon page, you can congure the network
parameters of master staons, SIP servers and management centers of the same
LAN. The devices can be linked to the door staon and realize the linkage between
these devices.
Steps
1.
Click Linked Network Conguraon to enter linked network conguraon page.
Figure 6-13 Linked Device Network
2.
En
ter the Master Staon IP Adderss, (Main) Door Staon IP Address, SIP Ser
ver
IP Address, Security Control Panel IP Address and Port No.
3.
Select the main door staon type from the drop-down list.
4.
Click Sa
ve to enbale the sengs.
Note
Aer adding master
staon IP Address, the linkage between indoor staon
and master staon can be realized.
Aer adding the door staon
IP Address, the video intercom between indoor
staons of same building can be realized.
Aer adding SIP Server Address IP, the video intercom of same community:
video in
tercom between indoor staons of dierent building, calling indoor
staon from outer door staon and video intercom between management
center and indoors.
Aer adding management center IP Address, the events can be uploaded to
the manag
ement center.
For indoor extension, only parameter about the main indoor staon should
be congured.