106 
 
4.3 Disarming 
You can disarm the system with keypad, keyfob, Tag, client software, or mobile client. 
Disarming Indication 
The arming/disarming indicator flashes 30s while the user successfully disarm the system through 
the entry/exit route. 
The system will report the disarming result after the operation completed. 
Entry Delay Duration 
Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1. 
Early Alarm 
If either the intrusion or tampering alarm occurs on the enter/exit route when the AX HYBRID PRO   
is in the status of entry delay, the AX HYBRID PRO    then enters the early alarm mode. 
The early alarm duration can be set (> 30s). 
The AX HYBRID PRO    will reports the alarm only if the alarm event lasts over the duration of early 
alarm with the addition of entry delay. 
4.4 SMS Control 
You can control the security system with SMS, and the command is shown below.   
SMS format for Arming/disarming/silencing alarm: 
{Command} + {Operation Type} + {Target} 
Command: 2 digits, 00- Disarming, 01- Away arming, 02- Stay arming, 03- Silencing alarm 
Operation type: 1- Area Operation 
Target: No more than 3 digits, 0-Operation for all areas, 1-Operation for area 1(zone1), and the 
rest can be deduced by the analogy.