Page #116 background imageLoading...
Page #116 background image
109
View status of zones which displays triggered/fault.
Solution:
Reset the detector.
A.4 Problems While Arming
A.4.1 Failure in Arming (When the Arming Process is Not Started)
Fault Description:
When the panel is arming, prompt arming fails.
Solution:
The panel does not enable "forced arming", and when there is a fault in the zone, the arming will
fail. Please turn on the "forced arming" enable, or restore the zone to the normal status.
A.5 Operational Failure
A.5.1 Failed to Enter the Test Mode
Fault Description:
Failed to enable test mode, prompting "A fault in the zone".
Solution:
Zone status, alarm status or zone power is abnormal.
A.5.2 The Alarm Clearing Operation on the Panel Does Not Produce the
Alarm Clearing Report
Fault Description:
The alarm clearing operation on the panel does not produce the alarm clearing report.
Solution:
In the absence of alarm, no report will be uploaded for arm clearing.
A.6 Mail Delivery Failure
A.6.1 Failed to Send Test Mail
Fault Description:
when configure the mail information, click "test inbox" and prompt test fails.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-PHA64-LP and is the answer not in the manual?

HIKVISION DS-PHA64-LP Specifications

General IconGeneral
Wi-FiYes
Wi-Fi frequency2.4 GHz
Wi-Fi standards802.11b, 802.11g, Wi-Fi 4 (802.11n)
Number of alarm zones64
Connectivity technologyWired & Wireless
Operating temperature (T-T)-10 - 40 °C
Number of simultaneous users62 user(s)
Operating relative humidity (H-H)10 - 90 %
Number of simultaneously connected devices (max)-
Batteries includedNo
Number of door/window sensors- pc(s)
Mounting typeWall
Product colorWhite
Housing materialPlastic
Battery life36 h
Alarm current2000 mA
Input voltage100 - 240 V
Battery voltage12 V
Battery capacity7000 mAh
Weight and Dimensions IconWeight and Dimensions
Alarm control panel weight997 g
Alarm control panel dimensions (W x D x H)261 x 86.4 x 199 mm

Related product manuals