123
SIA code
CID code
Description
XL (The serial number of
output module starts from 1,
of keypad starts from 101, of
tag reader starts from 201, of
transmitter starts from 301)
1381 (The serial number of
output module starts from 1,
of keypad starts from 101, of
tag reader starts from 201, of
transmitter starts from 301)
Device Offline
XC (The serial number of
output module starts from 1,
of keypad starts from 101, of
tag reader starts from 201, of
transmitter starts from 301)
3381 (The serial number of
output module starts from 1,
of keypad starts from 101, of
tag reader starts from 201, of
transmitter starts from 301)
Device Restored
LT
1351
Main Signalling Path Fault
LR
3351
Main Signalling Path Restored
LT
1352
Backup Signalling Path Fault
LR
3352
Backup Signalling Path Restored
AM
1354
Telephone Line Disconnected
CU
3354
Telephone Line Connected
AN
1382
BUS Supervision Fault
CV
3382
BUS Supervision Restored
1380
3380
TA
1144
Lid Opened
TR
3144
Lid Restored
Zone Open-circuit Alarm
Zone Short-circuit Alarm
OP
1401
Disarmed
CL
3401
Armed
OA
1403
Auto Disarmed
CA
3403
Auto Armed
BC
1406
Alarm Silenced
CW
3408
Instant Arming
CS
1409
Keyswitch Zone Disarming
OS
3409
Keyswitch Zone Arming
NL
3441
Armed in home mode
CX
3442
Forced Arming
Turn On Output by Schedule
Turn Off Output by Schedule
CT
1452
Late to Disarm
CD
1455
Auto Arming Failed
Turning On Output Failed
Turning Off Output Failed
Auto Disarming Failed
1556
Network Change
QB
1570
Bypassed

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-PHA64-LP and is the answer not in the manual?

HIKVISION DS-PHA64-LP Specifications

General IconGeneral
Wi-FiYes
Wi-Fi frequency2.4 GHz
Wi-Fi standards802.11b, 802.11g, Wi-Fi 4 (802.11n)
Number of alarm zones64
Connectivity technologyWired & Wireless
Operating temperature (T-T)-10 - 40 °C
Number of simultaneous users62 user(s)
Operating relative humidity (H-H)10 - 90 %
Number of simultaneously connected devices (max)-
Batteries includedNo
Number of door/window sensors- pc(s)
Mounting typeWall
Product colorWhite
Housing materialPlastic
Battery life36 h
Alarm current2000 mA
Input voltage100 - 240 V
Battery voltage12 V
Battery capacity7000 mAh
Weight and Dimensions IconWeight and Dimensions
Alarm control panel weight997 g
Alarm control panel dimensions (W x D x H)261 x 86.4 x 199 mm