60
Note
You can set 2 different time durations in System Options Schedule & Timer.
Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1.
You can set Stay Arm Delay Time for the delay zone.
Panic Zone
24-hour active zone, whether armed or not. Report panic alarm after triggering. It is usually
used in the sites equipped with panic button, smoke detector and glass-break detector.
Medical Alarm
24-hour active zone, whether armed or not. Report medical alarm after triggering.
Fire Zone
24-hour active zone, whether armed or not. Report fire alarm after triggering.
Gas Zone
24-hour active zone, whether armed or not. Report gas alarm after triggering.
Follow Zone
The zone acts as delayed zone when it detects triggering event during system Entry Delay,
while it acts as instant zone otherwise.
Keyswitch Zone
-By Trigger Time: Change the arming and disarming status after each trigger. For example, in
the disarmed status, if the zone is triggered, the linked area will be armed. Trigger the zone
again and the area will be disarmed.
-By Zone Status: You need to choose to arm or disarm the linked area after the zone is
triggered.
In the case of the tampering alarm, the arming and disarming operation will not be triggered.
Disabled Zone
Zone disabled ignoring any alarm event. It is usually used to disable faulty detectors.
24-hour Zone
The zone activates all the time with sound/light output when alarm occurs, whether it is
armed or not. It is usually used in fire hazardous areas equipped with smoke detectors and
temperature sensors.
Timeout Zone
The zone activates all the time. When this zone has been triggered or restored and exceeds
the set time, an alarm will be generated.
It can be used in places equipped with magnetic contacts that require access but for only a
short period (e.g., fire hydrant box's door or another external security box door).
-Not-Triggered Zone Alarm: If the zone is not triggered for the set time, it will alarm.
-Alarm on Zone Activated: If the zone is triggered for the set time, it will alarm.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-PHA64-LP and is the answer not in the manual?

HIKVISION DS-PHA64-LP Specifications

General IconGeneral
Wi-FiYes
Wi-Fi frequency2.4 GHz
Wi-Fi standards802.11b, 802.11g, Wi-Fi 4 (802.11n)
Number of alarm zones64
Connectivity technologyWired & Wireless
Operating temperature (T-T)-10 - 40 °C
Number of simultaneous users62 user(s)
Operating relative humidity (H-H)10 - 90 %
Number of simultaneously connected devices (max)-
Batteries includedNo
Number of door/window sensors- pc(s)
Mounting typeWall
Product colorWhite
Housing materialPlastic
Battery life36 h
Alarm current2000 mA
Input voltage100 - 240 V
Battery voltage12 V
Battery capacity7000 mAh
Weight and Dimensions IconWeight and Dimensions
Alarm control panel weight997 g
Alarm control panel dimensions (W x D x H)261 x 86.4 x 199 mm