Purpose:
When the mini PTZ camera is taken to another time zone, you can use the Time Zone
function to adjust the time. The time will be adjusted according to the original time and the
time difference between the two time zones.
From the Time Zone drop-down menu as shown in Figure 6-42, select the Time Zone in
which the mini PTZ camera locates.
Figure 6-42 Time Zone Settings
Configuring RS-485
Purpose:
The RS-485 serial port is used to control the PTZ of the camera. The configuring of the PTZ
parameters should be done before you control the PTZ unit.
Steps:
1. Enter RS-485 Port Setting interface:
Configuration> Advanced Configuration> System > RS485
Figure 6-43 RS-485 Settings
2. Set the RS-485 parameters and click to save the settings.
The Baudrate, PTZ Protocol and PTZ Address parameters of the mini PTZ camera should be
exactly the same as those of the control device.