Before You Start
Note
Indoor Passage Blockage Detecon and Fire Source Detecon will be out of service when On/O
Duty Detecon is enabled.
Steps
1.
Click Conguraon → Event → Smart Event → On/O Work Detecon .
2.
Check Enable.
3.
Set detecon area and disabled area.
1) Click Draw Detecon Area/Draw Disabled Area.
2)
Le-click to draw a convex quadrilateral.
3) Repeat step a and step b to draw less than 4 detecon areas/disabled areas.
4)
Oponal: You can edit the areas you draw as follows.
●
Hover mouse inside a zone and drag to change its
locaon.
●
Hover mouse on the vertexes of an area and drag to adjust the their
locaons.
●
Click Clear All to delete all areas exist.
Device will process smart detecon and analysis on events in detecon areas and neglect
feedbacks from disabled areas.
4.
Set
detecon parameters.
Number of Alarm People Threshold
If the detected number of
sta in the detecon zone is less than the lower limit sengs, the
alarm will be triggered.
O Work Detecon Time (s)
If the number of o-work sta is under the sengs and the duraon reaches the me
sengs,
the re alarm will be triggered.
Sensivity
The more sensive the detecng funcon is, the more easily the alarm will be triggered and
the more likely to misidenfy.
5.
Set arming schedule. See Set Arming Schedule .
6.
Set linkage method. See Linkage Method Sengs .
7.
Click Save.